Traffic Congestion Drives High Nitrogen Dioxide Occupational Risks in Alexandria Hospitals

2 hours ago 12

PROTECT YOUR DNA WITH QUANTUM TECHNOLOGY

Orgo-Life the new way to the future

  Advertising by Adpathway

Outdoor motor vehicle traffic serves as the primary source of indoor nitrogen dioxide concentrations within public hospitals in Alexandria, Egypt, elevating occupational hazards to high levels in facilities surrounded by heavily congested roadways. Conducted across four public hospitals located along corridors with distinct traffic patterns, the cross-sectional investigation revealed that indoor nitrogen dioxide levels tracked surrounding vehicular congestion, with the highest exposure occurring during morning shifts in warmer months. The research team evaluated how roadway emissions penetrate clinical and administrative workspaces, observing that staff in heavy traffic zones faced elevated chemical concentrations exceeding those in less congested areas. These findings emphasize the vulnerability of healthcare facilities situated downwind of major thoroughfares, establishing a clear link between external vehicle density and indoor occupational exposures.

The study addressed critical gaps in indoor air research, an area prioritized by the United States Environmental Protection Agency as a leading environmental health challenge. In Egypt, evaluations of indoor environmental quality remain limited, particularly in sensitive settings such as public medical complexes. While nitrogen dioxide represents a prevalent traffic pollutant, investigators have rarely examined it as an occupational hazard within hospitals, where staff experience sustained daily exposures. Maintaining adequate hospital indoor air quality directly supports Sustainable Development Goal 3, which promotes healthy lives and well-being for all ages. Healthcare facilities represent unique ecosystems distinct from commercial structures, making air quality essential for protecting patients from complications and shielding personnel from sick building syndrome symptoms including headaches, fatigue, and mucosal irritation.

From a health and chemical stability perspective, nitrogen dioxide constitutes the most critical species among nitrogen oxides, entering hospital interiors primarily through outdoor traffic exhaust and kitchen activities. Research documented by the World Health Organization shows that inhaling the gas irritates ocular, nasal, and respiratory systems. In healthy individuals, concentrations below five hundred micrograms per cubic meter produce no significant health impairments, though symptoms like coughing worsen among asthmatics. At concentrations between five hundred and two thousand micrograms per cubic meter, individuals experience increased acute respiratory complaints and diminished pulmonary function, marked by decreased forced expiratory volume in one second. Above two thousand micrograms per cubic meter, studies report acute bronchitis, bronchopneumonia, reduced arterial oxygen pressure, and heightened airway resistance.

To evaluate occupational threats, researchers utilized a risk assessment framework designed to determine the likelihood and severity of adverse health events. Risk assessment identifies and characterizes exposures to calculate objective risk factors that guide targeted workplace controls. Exposure likelihood was scored on a three-point scale reflecting time spent in rooms relative to six-hour shifts, using a threshold of seventy-five percent duration. Severity was categorized into three tiers reflecting minor, moderate, or major clinical effects. By multiplying likelihood and severity scores using a three-by-three matrix, the team generated color-coded risk factors from one to nine. This system categorized workplace conditions into low risk for scores of one to two, moderate risk for three to four, high risk for six, and very high risk for nine.

The cross-sectional investigation was conducted between August 2020 and January 2021, capturing operational conditions across hot and cold seasons in Alexandria. Researchers categorized urban zones based on vehicle speeds: heavy traffic from zero to twenty kilometers per hour, moderate traffic from twenty to forty kilometers per hour, and low traffic exceeding forty kilometers per hour. A fourth category encompassed the coastal on-sea road corridor, where vehicle speeds also exceeded forty kilometers per hour. The team randomly selected one public hospital from each category containing an eligible facility, yielding four institutions. This sample size aligned with prior air quality investigations, allowing the authors to evaluate how differing traffic congestion levels and coastal marine environmental factors influence indoor nitrogen dioxide penetration.

All four hospitals bordered main thoroughfares and were situated in areas devoid of industrial activity or alternative combustion sources besides traffic. The heavy traffic hospital, at latitude 31.22 degrees and longitude 29.96 degrees, occupied a congested primary road and side street, with a public parking lot directly facing its gates. The moderate traffic hospital stood at latitude 31.20 degrees and longitude 29.92 degrees, bordered by four moderate-traffic arterial roads. The low traffic facility, at latitude 31.27 degrees and longitude 30.03 degrees, was bordered by three low-traffic roads and flanked by another healthcare center. The on-sea hospital occupied latitude 31.21 degrees and longitude 29.88 degrees along the seafront in an active tourist district. Crucially, all four facilities were positioned downwind of their nearby arterial thoroughfares during the study.

Air quality sampling was conducted during six-hour morning shifts from eight in the morning until two in the afternoon, capturing peak hospital staff density and morning traffic congestion. Technicians placed sampling devices at room centers away from barriers at a height of approximately 1.5 meters, excluding areas near kitchens or cafeterias to eliminate confounding indoor combustion sources. Sampling procedures followed National Institute for Occupational Safety and Health standard method 6014, drawing air through personal sampling pumps and twenty-five-milliliter standard bubblers at flow rates between 0.2 and 1.0 liters per minute. The team sampled diverse settings, including outpatient clinics, administrative offices, pharmacies, patient rooms, emergency units, intensive care units, operating rooms, and clinical laboratories. Quality control included adherence to standard operating procedures alongside routine instrument calibration.

Across the surveillance program, researchers gathered seventy-six indoor measurements, comprising twenty-two readings from the low traffic hospital, twenty-two from the heavy traffic facility, eighteen from the moderate traffic site, and fourteen from the on-sea hospital. The Kolmogorov-Smirnov test confirmed that indoor nitrogen dioxide concentrations and calculated risk factors were normally distributed, allowing data expression as means and standard deviations. A One-Way ANOVA test identified statistically significant variations in nitrogen dioxide concentrations across the four hospital settings. Subsequent post-hoc comparisons showed that concentrations at the on-sea hospital differed significantly from heavy and moderate traffic institutions, while showing no significant difference compared to the low traffic hospital. Additionally, Spearman rank correlation demonstrated a strong, statistically significant relationship between traffic congestion and indoor nitrogen dioxide levels, yielding a coefficient of positive 0.885.

Measured indoor concentrations revealed substantial variations linked to ambient traffic volume and season. At the heavy traffic hospital, indoor concentrations reached 827.27 plus or minus 39.27 micrograms per cubic meter during hot months and 528.18 plus or minus 32.5 during cold months, representing a statistically significant difference. The moderate traffic facility recorded 471.11 plus or minus 6.0 in hot months and 363.33 plus or minus 5.0 in cold months. At the on-sea hospital, concentrations measured 367.1 plus or minus 49.9 during hot months and 242.86 plus or minus 38.61 in cold months, while the low traffic hospital recorded 292.72 plus or minus 22.4 and 240.0 plus or minus 18.44 micrograms per cubic meter across respective periods. Elevated hot-month levels reflected summer tourist traffic and temperature-accelerated nitrogen dioxide synthesis.

Translating concentrations into occupational risk factors revealed pronounced hazard disparities across the studied facilities. At the heavy traffic hospital, risk factors ranged from four to six, falling within medium to high-risk categories, with 72.7 percent of locations exhibiting high risk during hot months and 63.6 percent in cold months. In contrast, risk factors at the moderate, low, and on-sea traffic hospitals ranged from two to three, reflecting low-to-moderate risk. Moderate risk occurred across 77.8 percent of rooms in the moderate traffic hospital, 57.1 percent in the on-sea hospital, and 54.5 percent in the low traffic facility, without seasonal variation. Analysis of variance demonstrated significant variations in risk factors between the heavy traffic hospital and other facilities, while Spearman correlation analysis revealed a strong positive correlation of positive 0.73 between traffic congestion and calculated risk factors.

Comparing these outcomes with international literature provides broader context for traffic pollution in clinical environments. The Alexandria observations correspond with research from the Netherlands showing higher nitrogen dioxide concentrations along busy highways, as well as studies in Athens and Paris linking hot-month pollutant increases to solar radiation and photochemical activity. In contrast, results diverged from Turkish studies that identified wintertime pollution peaks driven by heating emissions. When evaluated against a Nigerian study of laboratory workers that reported risk factors of six and nine, the Alexandria heavy traffic hospital exhibited comparable high-risk burdens arising entirely from vehicle exhaust. Furthermore, risk factors in Alexandria’s heavy traffic hospital surpassed those documented in a 2006 study across Greater Cairo homes and a Saudi Arabian university hospital investigation, highlighting the unique severity of congested medical environments.

The authors noted that their study was limited to evaluating nitrogen dioxide and centered strictly on occupational exposures, making it unsuitable for assessing risks to patients and visitors. To mitigate occupational hazards, researchers recommended installing mechanical ventilation systems equipped with high-efficiency air filtration to prevent outdoor pollutants from infiltrating clinical workspaces. Implementing urban traffic management strategies, such as establishing one-way traffic systems and rerouting vehicles away from hospital zones, can further alleviate surrounding congestion. In addition, expanding landscaped green buffers around hospital grounds can help absorb nitrogen dioxide before it penetrates indoor spaces. For future healthcare infrastructure, urban planners should select upwind construction sites situated away from major roadways, while future research should incorporate multi-pollutant and quantitative risk assessment methods to evaluate non-occupational populations including inpatients and visitors.

Subject of Research: Occupational nitrogen dioxide exposure and risk assessment in public hospitals across varying traffic zones in Alexandria, Egypt

Article Title: Indoor occupational risk assessment of traffic-related nitrogen dioxide in public hospitals, Alexandria, Egypt

Article References: Abd El-Latef, E. M. A., Kamel, A.-A., Zaki, G. R., Issa, A. I., & Abdelraheem, A. (2026). Indoor occupational risk assessment of traffic-related nitrogen dioxide in public hospitals, Alexandria, Egypt. Journal of the Egyptian Public Health Association, 101(1), Article 9. https://doi.org/10.1186/s42506-025-00202-1

Image Credits: AI Generated

DOI: 10.1186/s42506-025-00202-1

Keywords: nitrogen dioxide, hospital indoor air quality, occupational exposure, traffic-related air pollution, Alexandria Egypt, public hospitals, risk assessment matrix, air sampling, NIOSH 6014, seasonal air quality variation, mechanical ventilation, pulmonary function, sick building syndrome, traffic congestion levels, environmental health, personal sampling pump, healthcare facility planning